DME

Aspire Active Air Bari 10

Alternating Mattress Replacement
Call for pricing

The Aspire Lifecomfort Active Air BARI 10 is an electrically operated Alternating Mattress Replacement offering a suite of features for a patient at high to very high risk of pressure injury. Ease of use, functionality, service ability and cleaning practicality are key features of this product.

This Alternating Mattress Replacement is appropriate for Bariatric adult patient care and should only be used under the instruction of a carer or health professional where concerns exist around patient safe use.

The mattress is intended to help and reduce the incidence of pressure injuries while optimising patient comfort. The mattress can be used in a variety of environments including, but not limited to in home care, aged care and hospital, specifically for Bariatric patients.

Key Features

  • Patient weight range of this mattress replacement is 30-450kg, this should not be exceeded at any time.
  • 1-in-2 and 1-in-4 alternating air cycles provides acute level therapy for maximum pressure  redistribution and wound management.
  • Turning Cycle – With the ability to turn a patient, the Product ensures safe patient transfer and lateral movement, improving manual handling and wound therapy outcomes.
  • Quick Inflation Blower Pump – High powered mattress pump ensures rapid inflation and the ability to effectively support loads up to 450kg.
  • AutoLock – The control panel automatically locks if not touched for 2 minutes preventing accidental changes to modes and settings.
  • AutoProtect - When the head of the bed is raised to 25º or more, air pressure automatically increases by +10mmHg. When the head of the bed is raised to 45º or more, air pressure automatically increases by +15mmHg to prevent bottoming out.
  • 24 Hour Transport - In the event of a power failure, patients can remain on the inflated surface for up-to 24 hours.
  • Easy-to-read LCD - Clear LCD screen provides concise information on cycle time selections, as well as operating mode and fault conditions.
  • Multi-stretch, Vapour Permeable Cover – Easy to clean cover is multi-stretch and breathable, reducing friction and shear whilst optimising skin microclimate.
  • Welded Seams & Zip Protection – Prevents fluid and bacterial ingress into the system, facilitating stringent infection control measures.
  • Rapid Release CPR – Allows quick deflation for cardio-pulmonary resuscitation in emergency situations.
  • Audible & Visual Alarms – Activate immediately if a problem occurs, maximising peace of mind and reducing patient risk.
  • Variable Speed Pump –The pump automatically runs at the minimum speed required for effective pressure care to reduce vibration and noise which improve patient sleep quality.
  • Variable Cycle Times – A choice of 10, 15 or 20 minute cycles of alternating mode and pulsate mode, and 10 to 95 minute cycles for turning mode to meet the needs and comfort requirements for a wide range of patients.
  • Simple Cell Connections – O-ring connections make maintenance hassle and tool free.
  • Hassle Free Pump Maintenance – Modular Pump design ensures Pumps can be serviced and returned to use quickly minimizing downtime.
  • Power Cord Protection – L shaped connection coupled with the protector function, significantly
    reduce the risk of the power cord becoming loose and getting damaged.
  • Cable Management – Power cable retainer loops offer effective cable management for the removal of trip hazards and cable damage.
  • If placed in static mode, the system will reduce to 70% of pressure level depending on comfort settings chosen.
  • Cell retention band prevents the inadvertent movement or separation of the cells that could lead to friction and shear.

 

 

Length

Width

Height

SWL

Active Air BARI 10 - Single

2000 mm

900mm

270mm

30kg – 450kg

Active Air BARI 10 - King Single

2000 mm

1070mm

270mm

30kg – 450kg

Active Air BARI 10 - Super King Single

2000 mm

1230mm

270mm

30kg – 450kg

 

The Aspire Lifecomfort Active Air BARI 10 is an electrically operated Alternating Mattress Replacement offering a suite of features for a patient at high to very high risk of pressure injury. Ease of use, functionality, service ability and cleaning practicality are key features of this product.

This Alternating Mattress Replacement is appropriate for Bariatric adult patient care and should only be used under the instruction of a carer or health professional where concerns exist around patient safe use.

The mattress is intended to help and reduce the incidence of pressure injuries while optimising patient comfort. The mattress can be used in a variety of environments including, but not limited to in home care, aged care and hospital, specifically for Bariatric patients.

Key Features

  • Patient weight range of this mattress replacement is 30-450kg, this should not be exceeded at any time.
  • 1-in-2 and 1-in-4 alternating air cycles provides acute level therapy for maximum pressure  redistribution and wound management.
  • Turning Cycle – With the ability to turn a patient, the Product ensures safe patient transfer and lateral movement, improving manual handling and wound therapy outcomes.
  • Quick Inflation Blower Pump – High powered mattress pump ensures rapid inflation and the ability to effectively support loads up to 450kg.
  • AutoLock – The control panel automatically locks if not touched for 2 minutes preventing accidental changes to modes and settings.
  • AutoProtect - When the head of the bed is raised to 25º or more, air pressure automatically increases by +10mmHg. When the head of the bed is raised to 45º or more, air pressure automatically increases by +15mmHg to prevent bottoming out.
  • 24 Hour Transport - In the event of a power failure, patients can remain on the inflated surface for up-to 24 hours.
  • Easy-to-read LCD - Clear LCD screen provides concise information on cycle time selections, as well as operating mode and fault conditions.
  • Multi-stretch, Vapour Permeable Cover – Easy to clean cover is multi-stretch and breathable, reducing friction and shear whilst optimising skin microclimate.
  • Welded Seams & Zip Protection – Prevents fluid and bacterial ingress into the system, facilitating stringent infection control measures.
  • Rapid Release CPR – Allows quick deflation for cardio-pulmonary resuscitation in emergency situations.
  • Audible & Visual Alarms – Activate immediately if a problem occurs, maximising peace of mind and reducing patient risk.
  • Variable Speed Pump –The pump automatically runs at the minimum speed required for effective pressure care to reduce vibration and noise which improve patient sleep quality.
  • Variable Cycle Times – A choice of 10, 15 or 20 minute cycles of alternating mode and pulsate mode, and 10 to 95 minute cycles for turning mode to meet the needs and comfort requirements for a wide range of patients.
  • Simple Cell Connections – O-ring connections make maintenance hassle and tool free.
  • Hassle Free Pump Maintenance – Modular Pump design ensures Pumps can be serviced and returned to use quickly minimizing downtime.
  • Power Cord Protection – L shaped connection coupled with the protector function, significantly
    reduce the risk of the power cord becoming loose and getting damaged.
  • Cable Management – Power cable retainer loops offer effective cable management for the removal of trip hazards and cable damage.
  • If placed in static mode, the system will reduce to 70% of pressure level depending on comfort settings chosen.
  • Cell retention band prevents the inadvertent movement or separation of the cells that could lead to friction and shear.

 

 

Length

Width

Height

SWL

Active Air BARI 10 - Single

2000 mm

900mm

270mm

30kg – 450kg

Active Air BARI 10 - King Single

2000 mm

1070mm

270mm

30kg – 450kg

Active Air BARI 10 - Super King Single

2000 mm

1230mm

270mm

30kg – 450kg